The main construction quality problems of LED inground light are water penetration of lamps and intermediate junction box of lines. Therefore, when planning the construction plan of LED inground light, the power supply line should adopt the appropriate way of connection to minimize the intermediate joint. When the middle joint is unavoidable, it is necessary to find a way to set up a junction box in an appropriate position on the ground. When the light source is unpacked and assembled on the spot and connected, the sealing level of the light may be reduced due to the environment, improper operation and other reasons, leaving potential quality hazard. When necessary, it is critical to require the product to be equipped with a good light source and sufficient length of lamp holder line. Therefore, Alpha Lighting attach importance that a reasonable, comprehensive construction plan will improve the quality of the project.
Alpha Lighting believes that the implementation of the construction plan in the process, to supervise the use of the correct process operation methods, according to the national standard atlas construction is the most basic requirements. For example, according to the atlas requirements, the middle connector of the circuit must be set in the waterproof junction box. The atlas does not indicate how to block the waterproof junction box. The waterproof junction box is actually not waterproof because the cable bushing is connected to the waterproof junction box unless the bushing is closed for the entire line, which is difficult to do. Therefore, it is necessary to fill the waterproof junction box with stable electrical sealant.
The insulation resistance of the lamp should be tested one by one before installation and use. In addition to meeting the requirements of the specification (Above 2 megohm), the insulation resistance should also be compared with the average measured value of this batch of products. Individuals whose measured values are much lower than the average measured values are processed to ensure that the measured values are within the normal mass distribution values. In addition, the lamps and lanterns should be sealed before installation and use. The junction around the lamp cover and the cable inlet position of the lamps and lanterns should be sealed with the electrical sealing cement outside the user. The installation mode and civil environment of the lamps and lanterns shall meet the requirements of the product technical specifications.
Summer is the perfect time to embellish our outdoor courtyard. During warm summer nights, b...
Lighting plays a crucial role in creating a captivating ambiance and showcasing the true esse...
Take a look at the amazing Hilton hotel lighting projects. Our one-stop lighting approach ...
Are you a clothing retailer looking to enhance the ambiance and showcase your clothing line in th...
At ALPHALUCE, we take pride in delivering comprehensive lighting solutions for diverse ...
When it comes to designing a modern home, lighting is often an afterthought. However, pro...
As a lighting designer or a building lighting contractor, have you ever wondered how to crea...
As a leading lighting manufacturer, ALPHA LIGHTING offers comprehensive lighting solution...